Fixed-Mount Thermal Imaging Camera for Condition Monitoring and Fire Prevention

FLIR A310 f (Automation)

Model: FLIR A310 f, 15° FOV
Go to Product Support
product image

FLIR A310 f thermal camera can be installed almost anywhere to monitor the condition of your critical equipment and other valuable assets. Designed to help safeguard your plant and measure temperature differences, they allow you to see problems before they become costly failures—preventing downtime and enhancing worker safety.

  • Streaming and Control over Ethernet

    FLIR A310 f features the ability to stream video over Ethernet for live viewing on a PC, plus communication and power over Ethernet cable.

  • Built-In Analysis

    The A310 f offers spot, area, and difference temperature measurement, and can alarm as a function of analysis, internal temperature, or digital input.

  • Built for Rugged Environments

    A310 f is an extremely rugged system that meets IP66 requirements, protecting the camera from dust and water.

Specifications
Digital I/O connector type
6-pole jackable screw terminal
Digital Inputs
2 opto-isolated, 10–30 VDC
Digital Output Purpose
As function of ALARM, Output to ext. device (programmatically set)
Digital Outputs
2 opto-isolated, 10–30 VDC, max 100 mA
Ethernet Video Streaming
MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
f-number
1.3
Image Frequency
30 Hz
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
Accuracy
±4°C (±7.2°F) or ±4% of reading
Alarm Functions
6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output
Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Communication & Data Storage
Digital I/O connector type
6-pole jackable screw terminal
Digital I/O isolation voltage
500 VRMS
Digital I/O supply voltage
12/24 VDC, max 200 mA
Digital input purpose
Image tag (start/stop/general), Input ext. device (programmatically read)
Digital Inputs
2 opto-isolated, 10–30 VDC
Digital Output Purpose
As function of ALARM, Output to ext. device (programmatically set)
Digital Outputs
2 opto-isolated, 10–30 VDC, max 100 mA
Ethernet
Control, result and image
Ethernet Communication
TCP/IP socket-based FLIR proprietary
Ethernet Connector Type
RJ-45
Ethernet Image Streaming
16-bit 320 × 240 pixels @ 7-8 Hz- Radiometric
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 0
Ethernet Protocols
Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet Standard
IEEE 802.3
Ethernet Type
100 Mbps
Ethernet Video Streaming
MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
File Formats
Standard JPEG, 16-bit measurement data included
Storage Media
Built-in memory for image storage
Video Connector Type
Standard BNC connector
Video Out
Composite video output, PAL and NTSC compatible
Video Output
Composite video output, PAL /NTSC compatible
Imaging & Optical
Array format
320 × 240
Color Palettes
Color palettes (BW, BW inv, Iron, Rain)
Detector Pitch
25 µm
Detector Time Constant
Typical 12 ms
Detector Type
Focal Plane Array (FPA), uncooled microbolometer
Field of view (FOV)
25° × 18.8°
FLIR Screen-EST Mode
No
f-number
1.3
Focal Length
30.38 mm (1.2 in.)
Focus
Automatic or manual (built in motor)
Image Frequency
30 Hz
IR Resolution
320 × 240
Lens Identification
Automatic
Minimum Focus Distance
1.2 m (3.93 ft.)
Spatial resolution (IFOV)
1.36 mrad
Spectral Range
7.5–13 µm
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
Video Standard
CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Zoom
1–8× continuous, digital, interpolating zooming on images
Measurement & Analysis
Accuracy
±4°C (±7.2°F) or ±4% of reading
Alarm Functions
6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output
Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Area
10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
Atmospheric transmission correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Difference Temperature
Delta temperature between measurement functions or reference temperature
Emissivity Correction
Variable from 0.01 to 1.0
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
Isotherm
1 with above/below/interval
Measurement Corrections
Global and individual object parameters
Measurement Option
Measurement Mask / Filter Schedule response: File sending (ftp), email (SMTP)
Object Temperature Range
–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Optics Transmission Correction
Automatic, based on signals from internal sensors
Reference Temperature
Manually set or captured from any measurement function
Reflected apparent temperature correction
Automatic, based on input of reflected temperature
Set-up Commands
Date/time, Temperature°C/°F
Spot Meter
10.0
General
Automatic Heater
Clears window from ice
Base Mounting
TBA
Housing material
Aluminum
List of Contents
Cardboard box, Infrared camera with lens and environmental, housing, FLIR Sensors Manager download card, FLIR Tools & Utilities CD-ROM, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Packaging Size
534 x 207 x 230 mm (21.0 x 8.1 x 9.1 in.)
Size (L x W x H)
460 × 140 × 159 mm (18.1 × 5.5 × 6.3 in.)
Weight
5 kg (11.0 lb.)
Environmental & Certifications
Bump
5 g, 11 ms (IEC 60068-2-27)
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Encapsulation
IP 66 (IEC 60529)
Humidity (Operating and Storage)
IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
Operating Temperature Range
–25°C to +50°C (–13°F to +122°F)
Storage Temperature Range
–40°C to +70°C (–40°F to +158°F)
Vibration
2 g (IEC 60068-2-6)
Power
External Power Connector Type
2-pole jackable screw terminal
External Power Connector Type [heater]
2-pole jackable screw terminal
External Power Operation
The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
External Power Operation [heater]
24 VDC, 25 W max.
Voltage
Allowed range 10–30 VDC
Voltage [heater]
Allowed range 21-30 VDC
Find a Dealer

Find a Dealer

Ready to buy? See our list of dealers.

Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.